{"id":2132,"date":"2020-12-15T04:43:51","date_gmt":"2020-12-14T20:43:51","guid":{"rendered":"https:\/\/mccchains.com\/2020\/12\/09\/salt-spray-test-2"},"modified":"2025-10-19T22:30:52","modified_gmt":"2025-10-19T14:30:52","slug":"salt-spray-test","status":"publish","type":"post","link":"https:\/\/mccchains.com\/en\/salt-spray-test","title":{"rendered":"Anti-Corrosion Chain Testing Standard &#8211; Salt Spray Test"},"content":{"rendered":"<h2 style=\"line-height: 1.4;\"><span style=\"color: #085294; font-family: Arial;\"><span style=\"font-size: 20px;\"><b>| Why does the chain need to do the salt spray test?<\/b><\/span><\/span><\/h2>\r\n<p style=\"line-height: 1.4;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Carbon steel chains have good strength and wearing resistance. However, in corrosive environment, the chains are easily got rusted. Most of the corrosion is caused by the exposure to atmospheric environment, and the most common and destructive is salt spray corrosion.\u00a0<\/span><\/span><\/p>\r\n<p style=\"line-height: 1.4;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">With the advancements in metal anti-corrosion technology, MCC has introduced various anti-corrosive coatings, including nickel plated, zinc plated, GN, CRF coatings and so on.<\/span><\/span><\/p>\r\n<p style=\"line-height: 1.4;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">To assess the protection ability of coating against the corrosion, a testing method that is fair and close to corrosive condition of natural environment is necessary.<\/span><\/span><\/p>\r\n<p style=\"line-height: 1.4;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Since salt spray corrosion is the most common factor lead to rusted metal, scientists have developed Salt Spray Test (SST) to simulate the severely corrosive condition and examine the rusted process. Currently, the salt spray is one of the most widespread corrosion testing methods.<\/span><\/span><\/p>\r\n<h2 style=\"line-height: 1.4;\"><span style=\"font-family: Arial;\"><span style=\"font-size: 16px;\"><span style=\"color: #424242;\"><b>Extended Reading<\/b><\/span><\/span><\/span><\/h2>\r\n<ul>\r\n<li style=\"line-height: 1.4;\"><span style=\"font-family: Arial;\"><span style=\"font-size: 16px;\"><a href=\"https:\/\/blog.mccchains.com\/2020\/11\/09\/anti-corrosion-coating\" target=\"_blank\" rel=\"noopener\"><span style=\"color: #3984c6;\">Comparing Anti-rust Chains &#8211; Find Out the Most Suitable Application<\/span><\/a><\/span><\/span><\/li>\r\n<\/ul>\r\n<div style=\"line-height: 1.4;\"><span style=\"font-family: Arial;\">\u00a0<\/span><\/div>\r\n<div style=\"line-height: 1.4;\">\r\n<h2 style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 20px;\"><span style=\"color: #085294; font-family: Arial;\"><b>| Salt Spray Testing Standard<\/b><\/span><\/span><\/h2>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\">The standards clearly stipulate the information to carry out the test, such as temperature, moisture, concentration of salt water (sodium chloride, NaCl), pH, etc. Also, the salt spray test machine is required to be manufactured according to the standard.\u00a0<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\">\u00a0<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\">ASTM B117 and ISO 9227 are both commonly adopted international standard for salt spray testing. MCC has adopted ASTM B117 standard.<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px;\"><span style=\"color: #424242; font-family: Arial;\">\u00a0<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\"><b>ASTM B117<\/b>\uff1aASTM B117 standard is developed by American Society for Testing and Materials. It was supposedly used as early as 1914 with roots in the National Bureau of Standards, originally published in 1939 by ASTM, and became a standard from 1962. ASTM B117 is the oldest and the most widely used standard.\u00a0<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px;\"><span style=\"color: #424242; font-family: Arial;\"><b>\u00a0<\/b><\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\"><b>ISO 9227<\/b> : ISO 9227 standard is developed by International Organization for Standardization. There are some differences between ISO 9227 and ASTM B117. It is more commonly used in European countries.<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\">\u00a0<\/div>\r\n<div style=\"line-height: 1.4;\">\u00a0<\/div>\r\n<\/div>\r\n<table class=\"table table-bordered\">\r\n<tbody>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\">\u00a0<\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><b><span style=\"font-size: 16px;\">ASTM B117<\/span> <\/b><\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\"><b>ISO 9227<\/b><\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Density, g\/cm3<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">1.024286-1.037261@25\u00b0C<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">1.029-1.036@25\u00b0C<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"font-size: 16px;\">Mass of NaCl required per 1 L<\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">53 \u00b1 10.6 g<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">50 \u00b1 5 g<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Electrical conductivity<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Max 5.0 \u00b5S\/cm a<span style=\"font-size: 16px;\">t 25<\/span><\/span><\/span><span style=\"font-size: 16px;\">\u00b0C<\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Max 20 \u00b5S\/cm at 25 \u00b0C \u00b1 2 \u00b0C<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Allowable Limits for Impurity Levels in Sodium Chloride<\/span> <\/span><\/td>\r\n<td>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Total impurities \u22660.3%<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Halides (bromide, Fluoride and iodide) \u22660.1%<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Copper &lt; 0.3 ppm<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Anti-caking agents none added<\/span><\/span><\/p>\r\n<\/td>\r\n<td>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Total impurities\u22660.5%<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Copper +Nickel +Lead\u22660.005%(50ppm)<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Sodium iodide\u22660.1%<\/span><\/span><\/p>\r\n<p style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Anti-caking agents none added<\/span><\/span><\/p>\r\n<\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Specimens suspended angle<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">15-30\u00b0<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">15-25\u00b0<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Salt concentration<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\" colspan=\"2\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">5%<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">pH range<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\" colspan=\"2\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">6.5 to 7.2<\/span> <\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Temperature<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\" colspan=\"2\"><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">35 +\/- 2<\/span><\/span><span style=\"line-height: 18.5714px; font-size: 16px;\">\u00b0C<\/span><\/td>\r\n<\/tr>\r\n<tr>\r\n<td><span style=\"color: #424242; font-family: Arial;\"><span style=\"font-size: 16px;\">Atomization and Quantity of Fog<\/span> <\/span><\/td>\r\n<td style=\"text-align: center;\" colspan=\"2\"><span style=\"color: #424242;\"><span style=\"font-family: Arial;\"><span style=\"font-size: 16px;\">For each 80 cm2 of horizontal collecting area, there will be collected from 1.0 to 2.0 mL of solution per hour.<\/span><\/span> <\/span><\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<div style=\"line-height: 1.4;\">\u00a0<\/div>\r\n<div style=\"line-height: 1.4;\">\r\n<h2 style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 20px;\"><span style=\"color: #085294; font-family: Arial;\"><b>| Salt Spray Testing Method<\/b><\/span><\/span><\/h2>\r\n<h3 style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px;\"><span style=\"color: #424242; font-family: Arial;\"><b><span style=\"font-size: 16px;\">1.\u00a0<\/span><span style=\"font-size: 16px;\">Pictures of salt spray machine<\/span><\/b><\/span><\/span><\/h3>\r\n<p style=\"line-height: 1.4;\">\u00a0<\/p>\r\n<\/div>\r\n<div class=\"row\">\r\n<div class=\"col-md-4\"><img decoding=\"async\" style=\"width: 100%;\" title=\"\u9e7d\u9727\u8a66\u9a57\u6a5f\" src=\"https:\/\/mccchains.com\/wp-content\/uploads\/migra\/blog\/fe0952eb4f9e5653781f2707ae9016e5af440c4e.jpg\" alt=\"\u9e7d\u9727\u8a66\u9a57\u6a5f\" data-filename=\"\u9e7d\u9727\u8a66\u9a57\u6a5f\" \/><\/div>\r\n<div class=\"col-md-4\"><img decoding=\"async\" style=\"width: 100%;\" title=\"During salt spray testing\" src=\"https:\/\/mccchains.com\/wp-content\/uploads\/migra\/blog\/bfd6a879c09a09abd49eb6cf20c374238056cb85.jpg\" alt=\"During salt spray testing\" data-filename=\"During salt spray testing\" \/><\/div>\r\n<\/div>\r\n<div>\r\n<div>\r\n<h3 style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px;\"><span style=\"color: #424242; font-family: Arial;\"><b><span style=\"font-size: 16px;\">2.\u00a0<\/span><span style=\"font-size: 16px;\">Working principle of salt spray test machine<\/span><\/b><\/span><\/span><\/h3>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\">The salt spray test equipment is constructed as a &#8220;tower airflow spray device&#8221;. The spray nozzle adopts &#8220;Bernoulli&#8217;s principle&#8221; to provide compressed air from an external air source. The high-speed airflow, which is generated by spraying from the nozzle, forms a siphon and pulls the salt solution into the chamber through an atomizer. Atomized salt fog is sprayed upwards and fill in the chamber.<\/span><\/span><\/div>\r\n<div style=\"line-height: 1.4;\"><span style=\"line-height: 18.2px; font-size: 16px;\"><span style=\"color: #424242; font-family: Arial;\">\u00a0<\/span><\/span><\/div>\r\n<h2><span style=\"line-height: 18.2px; font-size: 20px;\"><span style=\"color: #085294;\"><b>| Salt Spray Test Result<\/b><\/span><\/span><\/h2>\r\n<div><img decoding=\"async\" style=\"width: 50%;\" title=\"Nickel plated salt spray test result\" src=\"https:\/\/mccchains.com\/wp-content\/uploads\/migra\/product\/d83acf4b56d4904904fea69252fd2fb17bc83c11.jpg\" alt=\"Nickel plated salt spray test result\" data-filename=\"Nickel plated salt spray test result\" \/><\/div>\r\n<div><span style=\"line-height: 18.2px;\"><span style=\"font-size: 16px;\"><span style=\"color: #424242;\">\u203b Nickel plated coating testing result<\/span><\/span><\/span><\/div>\r\n<div><span style=\"line-height: 18.2px;\"><span style=\"font-size: 16px;\"><span style=\"color: #424242;\">\u00a0<\/span><\/span><\/span><\/div>\r\n<h2><span style=\"font-size: 20px; line-height: 18.2px;\"><b><span style=\"color: #085294;\">| Application<\/span><\/b><\/span><\/h2>\r\n<div>\u00a0\r\n<ul>\r\n<li><span style=\"font-size: 16px; line-height: 18.2px;\"><b>Ensure the quality of anti-corrosive coating <\/b>: Make sure chains\u2019 anti-rust performance reach the standard.<\/span><\/li>\r\n<li><span style=\"font-size: 16px; line-height: 18.2px;\"><b>Improve the anti-rusted performance<\/b>: When improving the anti-corrosion coating, salt spray is used to find the best process.<\/span><\/li>\r\n<li><span style=\"font-size: 16px; line-height: 18.2px;\"><b>Develop new coating<\/b> : With the continuous development of corrosion resistant technology, salt spray test is the best method to examine the performance of new coating..<\/span><\/li>\r\n<li><span style=\"font-size: 16px; line-height: 18.2px;\"><b>Examine the chain lubricant protection against corrosion<\/b><\/span><\/li>\r\n<\/ul>\r\n<div style=\"font-size: 16px; line-height: 18.2px;\">\u00a0<\/div>\r\n\u00a0<\/div>\r\n<\/div>\r\n<\/div>\r\n<!-- ===================== CTA BUTTONS (add at the very bottom) ===================== -->\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 20px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-2ecae44e wp-block-buttons-is-layout-flex\" style=\"display: flex; flex-wrap: wrap; gap: 12px; justify-content: center;\">\r\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-text-color has-background\" style=\"background-color: #0b5ed7; color: #ffffff; padding: 12px 18px; border-radius: 10px; display: inline-block; font-weight: bold; letter-spacing: .2px; text-decoration: none;\" href=\"https:\/\/mccchains.com\/en\/anti-corrosion-coating\" target=\"_blank\" rel=\"noopener\"> Find more information about anti-rust chain <\/a><\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-text-color has-background\" style=\"background-color: #0b5ed7; color: #ffffff; padding: 12px 18px; border-radius: 10px; display: inline-block; font-weight: bold; letter-spacing: .2px; text-decoration: none;\" href=\"https:\/\/mccchains.com\/en\/products\/crf-corrosion-resistant-chain\" target=\"_blank\" rel=\"noopener\"> Looking for corrosion resistant chain? <\/a><\/div>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-spacer\" style=\"height: 24px;\" aria-hidden=\"true\">\u00a0<\/div>\r\n<!-- ===================== FAQ (add below the buttons) ===================== -->\r\n\r\n\r\n<h2 class=\"wp-block-heading\" style=\"color: #085294; font-family: Arial; font-size: 20px; line-height: 1.4;\"><b>| FAQ<\/b><\/h2>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q1: What is the Salt Spray Test (SST) and why is it used on chains?<\/strong> <br \/>\r\n\r\n SST is an accelerated corrosion test that atomizes a NaCl solution in a heated chamber to simulate severe atmospheric conditions. It helps evaluate how coatings (e.g., nickel plated, zinc plated, GN, CRF) protect chains in corrosive environments. <\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q2: Which standards are commonly used for SST?<\/strong> <br \/>\r\n\r\n ASTM B117 and ISO 9227 are widely used. This article references ASTM B117, which specifies chamber temperature, salt concentration (5%), pH, fog collection rate, specimen angle, and other parameters. <\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q3: Does a higher SST hour rating always mean better real-world performance?<\/strong> <br \/>\r\n\r\n Not necessarily. SST is a comparative lab method. Real service life also depends on temperature, humidity cycles, pollutants, cleaning chemicals, load, and lubrication. Use SST hours to compare coatings under the same standard, not as a direct lifespan guarantee. <\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q4: When should I choose CRF corrosion-resistant chain instead of standard plated chains?<\/strong> <br \/>\r\n\r\n Choose CRF when you need stronger protection in frequent washdown, coastal air, or areas with aggressive salts\/acids. For mild environments, nickel or zinc plating may be sufficient and more cost-effective. <\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q5: Do corrosion-resistant coatings affect chain strength?<br \/><\/strong> \r\n\r\n Thin protective coatings are designed to maintain mechanical properties within specification. Always check the datasheet for allowable working load and wear limits after coating. <\/div>\r\n\r\n\r\n\r\n<div class=\"wp-block-group is-layout-constrained wp-container-core-group-is-layout-ab0ad5cf wp-block-group-is-layout-constrained\" style=\"border: 1px solid #e6e6e6; border-radius: 10px; padding: 14px 16px; margin-top: 10px; margin-bottom: 10px;\"><strong>Q6: Any maintenance tips to reduce corrosion in service?<\/strong> <br \/>\r\n\r\n Keep chains clean, relubricate on schedule, avoid chloride-rich cleaners unless compatible, and protect idle equipment from condensation or salt fog. Selecting the right coating for your environment is the first step. <\/div>\r\n<!-- (Optional) Structured data for SEO: paste in a \"Custom HTML\" block if you want FAQ rich results.\r\n<script type=\"application\/ld+json\">\r\n{\r\n  \"@context\":\"https:\/\/schema.org\",\r\n  \"@type\":\"FAQPage\",\r\n  \"mainEntity\":[\r\n    {\"@type\":\"Question\",\"name\":\"What is the Salt Spray Test (SST) and why is it used on chains?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SST is an accelerated corrosion test that atomizes a NaCl solution in a heated chamber to simulate severe atmospheric conditions. It helps evaluate how coatings protect chains in corrosive environments.\"}},\r\n    {\"@type\":\"Question\",\"name\":\"Which standards are commonly used for SST?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"ASTM B117 and ISO 9227 are widely used. This article references ASTM B117, which specifies chamber temperature, salt concentration (5%), pH, fog collection rate, specimen angle, and other parameters.\"}},\r\n    {\"@type\":\"Question\",\"name\":\"Does a higher SST hour rating always mean better real-world performance?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Not necessarily. SST is a comparative lab method. Real service life also depends on temperature, humidity cycles, pollutants, cleaning chemicals, load, and lubrication.\"}},\r\n    {\"@type\":\"Question\",\"name\":\"When should I choose CRF corrosion-resistant chain instead of standard plated chains?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose CRF when you need stronger protection in frequent washdown, coastal air, or areas with aggressive salts\/acids. For mild environments, nickel or zinc plating may be sufficient and more cost-effective.\"}},\r\n    {\"@type\":\"Question\",\"name\":\"Do corrosion-resistant coatings affect chain strength?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Thin protective coatings are designed to maintain mechanical properties within specification. Always check the datasheet for allowable working load and wear limits after coating.\"}},\r\n    {\"@type\":\"Question\",\"name\":\"Any maintenance tips to reduce corrosion in service?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Keep chains clean, relubricate on schedule, avoid chloride-rich cleaners unless compatible, and protect idle equipment from condensation or salt fog.\"}}\r\n  ]\r\n}\r\n<\/script>\r\n-->","protected":false},"excerpt":{"rendered":"<p>Salt spray test is to examine corrosion resistance of coated chain. The article is to introduce the standard and method how the test is done.<\/p>\n","protected":false},"author":5,"featured_media":1227,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[166],"tags":[170,173,174,266,267],"class_list":["post-2132","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chain-knowledge","tag-roller-chain-knowledge","tag-chain-testing","tag-chain-quality","tag-anti-rust-chain-test","tag-anti-corrosion-chain-test"],"jetpack_featured_media_url":"https:\/\/mccchains.com\/wp-content\/uploads\/migra\/blog\/395b4336ecb007b1b11059b4cd6797eec397f8a2.jpg","_links":{"self":[{"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/posts\/2132","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/comments?post=2132"}],"version-history":[{"count":3,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/posts\/2132\/revisions"}],"predecessor-version":[{"id":4304,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/posts\/2132\/revisions\/4304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/media\/1227"}],"wp:attachment":[{"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/media?parent=2132"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/categories?post=2132"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/mccchains.com\/en\/wp-json\/wp\/v2\/tags?post=2132"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}